Cutting oil lifetime test
[Verification]
Type of a coolant
Manufacturer |
Nippon Quaker Chemical, Ltd |
Product name |
Microcut KD |
Verification starting time |
After the cutting oil change on June 13, 2008
The test of this unit was started on December 11. |
Degree of odor |
Odor Sensor XP-329IIIR by New Cosmos Electric Co., Ltd. |
Test for bacterium |
Bio Checker by SAN-AI OIL CO., LTD. |
[Cultivation]
- Set the heater inside box open at open at one face and measure with a digital thermometer.
- The temperature inside was kept around 30 degrees Celsius.
- Observe the status with keeping the condition for 48 hours.
[Experiment]
- Cultivation was started with the Bio Checker submerged in test liquid on December 8.
- The cultivation status was checked on December 10: The cultivation was decided to be continued, since the cultivation was not enough although the surface was slightly changed.
- Bacteria reproduced to 106 on the comparison table (Bio Checker decision table) by December 11.
[Experiment after setting this unit]
- Set and started to operate this unit on December 11 (24 hours).
- Test by Bio Checker on December 12 (1) (4) Measurement with Odor Sensor
- Test by Bio Checker on December 13 (2)
- Test by Bio Checker on December 14 (3) (5) Measurement with Odor Sensor
[Experiment results]
- Bacteria have decreased to 105. Anaerobic bacteria are considered to have reduced.
- Bacteria have decreased to 104. Anaerobic bacteria are considered to have reduced.
- The status 104 is still the same.
- Odor Sensor shows almost the same value of the air outside.
- Odor Sensor shows almost the same value of the air outside.
* Measurements with Bio Checker was under the same condition of the first measurement.
[Conclusion]
- The result for Odor Sensor was not enough: It may be due to the way of air aspiration.
- It can be felt that the odor reduced with smelling directly on the 3rd day.
Bacteria count |
Concentration |
- The bacteria count decrease can be seen.
- The concentration of cutting oil has been thickened (The concentration raised (about 20%) due to the pumped air and low humidity in the factory).
- The bacteria count is presumed to decrease, since the diluted cutting oil was added in order to recover the appropriate concentration of 10% after the measurement.